SPECIFICATIONS
MODEL
7450
7451
7452
AC WITHSTAND VOLTAGE
Output Rating 5KVAC/100mA Constant 500VA
Range
Resolution
Accuracy
Output Voltage, ACV
0 - 5000
1
±(2% of setting + 5V)
Output Frequency 50Hz/60Hz ±100ppm, User Selection
Output Waveform Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5
Output Regulation ± (1% of output + 5V), From no load to full load
SETTINGS
Hi-Limit AC Current, mA
0 - 99.99
0.01
±(2% of setting + 3counts)
Lo-Limit AC Current, mA
0 - 9.999
0.001
±(2% of setting + 3counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.3 - 999.9
(0=continuous)
0.1
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
AC Current Offset, mA 0 - 2.000 or Auto Set
DC WITHSTAND VOLTAGE (7451,7452 ONLY)
Output Rating 6KVDC/9999µA
Output Voltage, DCV 0 - 6000 1 ±(2% of setting + 5V)
Output Ripple <5%(6KV/9999µA at Resistive Load)
SETTINGS
Hi-Limit DC Current, µA
0 - 9999
1
±(2% of setting + 3counts)
Lo-Limit DC Current, µA
0 - 999.9
0.1
±(2% of setting + 3counts)
Ramp Time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
Dwell Time, second
0, 0.4 - 999.9
(0=continuous)
0.1
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
DC Current Offset, µA 0 - 200.0 or Auto Set
Ramp High Current ON/OFF, User Selection
Charge - Low Current, µA 0 - 350.0 or Auto Set
Discharge Time < 200 msec
INSULATION RESISTANCE
Output Rating 1KVDC/9999MΩ
Output Voltage, DCV
100 - 1000
1
±(2% of setting + 3V)
Hi-Limit Resistance, MΩ
0, 1 - 9999 (0=OFF)
1
±(2% of setting+2counts)at 500-1000VDC, 1 -1000 MΩ
±(8% of setting+2counts)at 500-1000VDC, 1000 -9999 MΩ
±(8% of setting+2counts)at 100-500VDC, 1 -1000 MΩ
Lo-Limit Resistance, MΩ
1 - 9999
1
Delay Time, second
0, 0.5 - 999.9
(0=continuous)
0.1
±(0.1% + 0.05sec)
Charge - Low Current, ?A
0 - 3.500 or Auto Set
GROUND BOND (7452 ONLY)
Output Rating 30A/600mΩ, 8V
Output AC Current, A
3.00 - 30.00
0.01
± (2% of setting +2 counts)
Output AC Voltage, V
3.00 - 8.00
0.01
± (2% of setting +3 counts)
Output Frequency 50Hz/60Hz ±100ppm, User Selection
SETTINGS
Hi-Limit Resistance, mΩ
0 - 150 (3 - 30A)
1
± (2% of setting +2 counts)
Lo-Limit Resistance, mΩ
0 - 600 (3 - 10A)
Lead Resistance Offset, mΩ
0 -200
1
± (2% of setting +2 counts)
Dwell Time, second
0, 0.5 - 999.9 sec (0 = continuous)
0.1
±(0.1% + 0.05sec)
MEASUREMENT
AC/DC Voltage, KV
0 - 6.00
0.01
±(1.5% of reading + 1count)
DC Voltage, V (IR)
100 - 1000
1
±(1.5% of reading + 3count)
AC Current Range, mA
0-3.500
0.001
±(2% of reading + 3counts)
3.00-99.99
0.01
±(2% of reading + 6counts)
DC Current Range, µA
0-350.0
0.1
± (2% of reading + 3counts)
300 - 3500
1
± (2% of reading + 2counts)
3000-9999
10
± (2% of reading + 6counts)
AC Current, A (GB)
0 - 35.00
0.01
±(2% of reading+2counts)
Resistance, , MΩ(IR)
1 - 9999
(Auto Range)
±(2% of reading+2counts)at 500-1000VDC, 1 -1000 MΩ
±(8% of reading+2counts)at 500-1000VDC, 1000 -9999 MΩ
±(8% of reading+2counts)at 100-500VDC, 1 -1000 MΩ
Resistance, , mΩ(GB)
0 - 600
1
±(2% of reading+2counts)
GENERAL
Input Voltage AC 100/115/200/230Vac±15%, 50/60Hz ± 5%, Fuse 15A
PLC Remote Control Input : Test , Reset , Memory1.2.3
Output : Pass , Fail , Processing
Memory 50 memories, 8 steps/memory
Display 20×2 LCD with back light
Key Lock To prevent unauthorized alteration of the test Parameters
Calibration Build-in software and external calibrated meters
Alarm Volume Setting Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume.
Rear Panel Output
YES
YES
YES
Built-in Scanner
-
-
-
External Scanner
-
YES
YES
Smart GFI
YES
YES
YES
Analog Meter
YES
YES
YES
RS232 Interface
-
Option
Option
GPIB Interface
-
YES
YES
Printer Interface
-
Option
Option
TUV-GS listed
YES
-
YES
CE Compliance
YES
-
YES
Environment
0-40℃, 20-80%RH
Dimension (W×H×D)
430×133×400 (mm)
430×133×400 (mm)
430×133×500 (mm)
Net Weight
28Kg
28Kg
32Kg
STANDARD ACCESSORIES
Power Cord(15A)
×1
Fuses
×2 (Including a spare contained in the fuse holder)
Hipot Test Lead ,1.5m(1101)
×1
×1
×1
Hipot Return Lead ,1.8m(1102)
×1
×1
-
Ground Bond Test Lead 30A
,1.5m(1103)
-
-
×1
Ground Bond Return Lead 30A
,1.5m(1104)
-
-
×1