品牌
生产厂家厂商性质
北京市所在地
V
Resistance, current double display
Good performance is stable, easy reading
All the test voltage ( 10/50/100/250/500/1000V ) test resistance results in reading, is removed from the old high resistance meter in different test voltage or different scale should be multiplied by the coefficient of the inconvenient trouble, allowing the measurement of high resistance as the multimeter is used to measure the general resistance of samples is simple.
Not only can measure high resistance and micro current
Wide application: applied to anti-static products such as anti-static shoes, anti-static plastic rubber products, computer room anti-static floor activities such as resistance testing electrical and electronic products insulation resistance measurement
Three, volume resistivity surface resistivity tester technical indicators
The 1 resistor measurement range: 0.01× 104 Ω~ 1× 1018 Ω.
The 2 current measurement range : 2 × 10-4A~ 1 × 10-16A
3 double header display: 3.1/2 LED display
4 built-in test voltage: 10V, 50V, 100V, 250, 500, 1000V
5 basic accuracy: 1% ( note )
6: use environment temperature: 0℃ ~ 40 ℃, relative humidity<80%
7 built-in test voltage: 10/50/100/250/500/1000V arbitrary switching
The 8 power supply forms: AC 220V, 50HZ, power consumption is about 5W
Four, volume resistivity surface resistivity meter working principle
According to the Ohm's law, the measured resistance is equal to voltage is applied through Rx V divided by the current I. The traditional high resistance meter is the working principle of measuring voltage V fixed, by measuring the current flows through the sampling resistor I to get the value of resistance. From Ohm's law can be seen, because the current I is inversely proportional to the resistance, but not proportional to the resistance, so the display value is nonlinear, namely the resistance to infinity, the current is zero, i.e., zero is∞, in the vicinity of the scale is very dense, with a low resolution. The scale is nonlinear. Because the measurement of different resistance, the voltage V also vary, so the average high resistance meter is poor accuracy, low resolution.
At the same time measure the voltage across the resistor V and the current through the resistor I, through the interior of the large scale integrated circuit to complete the voltage divided by the current calculation, and then the results obtained after A/D conversion to digital show resistance, even if the voltage across the resistor V and the current through the resistor I is changed at the same time, the display resistance value is not as common due to high resistance meter that measured voltage or current change of V I change, so, even if the measured voltage, resistance, power supply voltage is measured the changes in the results have little effect, the measurement accuracy is very high ( patent ), theoretically the error can be zero, while the actual error can be done a few thousandths or extremely few.
Typical application
1 measurements of anti-static shoes, conductive shoes resistance value
2, measurement of the antistatic material resistance and resistivity
3, measurement computer room with movable floor system resistance
4, measurement of insulation resistance ( rate)
5, photodiode dark current measurement
6, physics, optics and materials research
Canton company other insulating materials testing instruments:
BDJC-0-100KV dielectric breakdown testing instrument
BDJC series insulating materials at power frequencies of dielectric breakdown test instrument
BDJC series voltage dielectric strength test apparatus
BDJC series voltage breakdown testing instrument
BDJC series insulating paint film breakdown strength tester
BDJC capacitor voltage breakdown testing instrument
EST-121 volume surface resistivity measuring instrument
GDAT-A dielectric loss tester / dielectric constant test