The module has two signal input channels, A and B, each with a full-scale sensitivity of ±10 V DC. On receipt of a trigger command at the appropriate channel the input voltage is digitized to a 5 mV resolution. A computer coupled to the module can determine the value of the input voltage by sending a simple ASCII command. The 3½ digit panel meter on the 4161A can be switched to monitor either of the signal channels.
Input | |||
Channels | Two | ||
ADC Inputs | BNC front-panel connectors, A and B | ||
Input Impedance | 1 MΩ | ||
Input Full-Scale | ±10 V | ||
Accuracy | ±5 mV | ||
Linearity | ±5 mV | ||
ADC Trigger Inputs | BNC front-panel connectors, corresponding to channel A and channel B ADC inputs. Connectors are duplicated on rear-panel | ||
Trigger Thresholds | TTL. Triggers on rising edge of applied positive logic TTL pulse | ||
Digital Display | |||
Type | 3½ digit LED display showing (Measured voltage / 20) | ||
Display Selection | Switch selects channel A or channel B | ||
Computer Interfaces | |||
RS232 | DIP switch selectable baud rate, terminator, character echo, parity and data bits | ||
GPIB | DIP switch selectable address and terminator | ||
Status Indicators | Front panel LEDs indicate GPIB Talk, Listen, SRQ and Remote | ||
Command Set | Twelve mnemonic type commands allowing both asynchronous and synchronous readings. Digitized voltages are reported back to the computer in integer format, with ±2048 corresponding to an input voltage of ±10.24 V | ||
Output | |||
Busy Out | Rear-panel BNC connector generating TTL signal which under computer control will:- 1) Remain at logic 0 until a synchronized read command is issued by the computer. 2) Go to logic 1, releasing external trigger hold-off circuitry (such as can be provided by the SIGNAL RECOVERY model 9650A). 3) Return to logic 0 on receipt of a trigger signal at either the A or B ADC trigger inputs, and remain there while the measured value(s) are transferred back to the computer and thereafter until the next synchronized read command | ||
Analog Panel Meter | |||
Type | Edge-indicating meter monitoring the voltage at the associated front-panel analog input BNC connector. This meter is completely independent of the analog to digital converter functions | ||
Input Impedance | 10 kΩ | ||
Full-scale sensitivity | ±10 V | ||
Power Requirements | +24 V at 50 mA; -24 V at 50 mA +12 V at 600 mA; -12 V at 30 mA +6 V at 550 mA; -6 V at 10 mA | ||
Dimensions | |||
Height | 8¾" (222 mm) | ||
Width | 2¾" (70 mm) | ||
Depth | 9¾" (248 mm) | ||
Weight | 2.5 lb (1.14 kg) |